  • Core Switch Design Scheme Diagram

    Core Switch Design Scheme Diagram

    The multi-tier model is the most common model used in the enterprise today. This design consists primarily of web, application, and database server tiers running on various platforms including blade serv.


  • Signal diagram of a communication tower

    Signal diagram of a communication tower

    Radio masts and towers are typically tall structures designed to support for and, including. There are two main types: guyed and self-supporting structures. They are among the tallest human-made structures. Masts are often named after the broadcasting organizations that originally built them or currently use them.


  • Fiber Channel Card Connection Diagram

    Fiber Channel Card Connection Diagram

    The Fibre Channel physical layer is based on serial connections that use fiber optics to copper between corresponding pluggable modules. The modules may have a single lane, dual lanes or quad lanes that correspond to the SFP, SFP-DD and QSFP form factors. Fibre Channel does not use 8- or 16-lane modules (like CFP8, QSFP-DD, or COBO used in 400GbE) and there are no plans to use these expensive and comple.


  • Design Requirements for Power Distribution Box Circuits in Exhibition Halls

    Design Requirements for Power Distribution Box Circuits in Exhibition Halls

    The right enclosure depends on event size, load demand, socket layout, cable routing, and site conditions. IP rating, circuit protection, grounding, ventilation, and clear labeling are key buying points. Convention centers are unique in their energy demands. They require systems that can: Handle Variable Loads: Power requirements fluctuate significantly depending on the type and scale of the event. Support Specialized Equipment: Exhibitors often need dedicated power for lighting rigs, audiovisual. Event power enclosures protect breakers, outlets, and cables from rain, dust, impact, and public contact, helping large events run safely. As per their name, these systems are perfect for exhibition and show setups that require a timely power supply. Featuring higher amperage ratings of up to 140 amp for greater power and data capacity, these devices are designed to accommodate all your high-load utility services including power. Temporary electrical installation is a key component in the success of an event. By incorporating an optimized distribution logic from the design phase.

    [PDF Version]
  • Lateral Seismic Design of Cable Trays

    Lateral Seismic Design of Cable Trays

    Technical overview of seismic cable tray design considerations including bracing splice reinforcement movement accommodation cable retention and support verification. High-seismicity projects place much greater demands on cable tray systems than ordinary installations. INTRODUCTION large telecommunication company embarked on a program that included building a series of telecommunications facilities in the Seattle, Washington area. If these. Let's talk about Cable Trays Seismic Design. I'll share what I've learned about the design principles, methods, and how I put them into practice. When an earthquake happens, the ground really shakes. Copyright @ 1991 Electric Power Research Institute, Inc. Requests for copies of this report should be directed to the EPRI Distribution Center, 207 Coggins Drive. Electrical cables constitute one of the vital systems of power plants, as they are relied upon for the monitoring, control and operation of a great number of safety-related equip- ment.

    [PDF Version]
  • Case Study of Communication Tower Design

    Case Study of Communication Tower Design

    This comprehensive article examines the critical aspects of structural evaluation in telecommunications towers, addressing key considerations in design, load analysis, and safety protocols. The article encompasses various tower configurations, including lattice, monopole, and guyed structures. Failure of such structures i a major concern.


  • Types of Fire-Resistant Phenolic Cable Trays

    Types of Fire-Resistant Phenolic Cable Trays

    FRP cable tray is the support system for managing cables and protect cables from heating, rains and corrosive elements. There are two types, FRP ladder type cable tray and FRP channel cable tray. Cablofil cable tray is the preferred choice for the cable containment of low and high voltage electric cables where fire resistance is crucial - this includes cable basket tray systems for Prysmian FP (FP400 and FP600) and Draka Firetuf type cables. Cablofil fire resistant and fire proof cable. EAE Group of Companies started its journey in the electrical sector in 1973 with the establishment of EAE Elektrik. Electrical fires can spread rapidly through the cables within a tray system, which is why choosing the right material for your cable tray is paramount in reducing the risk. Let us know about your needs and wishes.

    [PDF Version]
  • What types of optical amplifiers are available from different suppliers

    What types of optical amplifiers are available from different suppliers

    The most common types are fiber amplifiers (such as the EDFA) and semiconductor optical amplifiers (SOAs). They are distinct from lasers in that they typically lack a resonant cavity and thus do not generate light on their own (ideally) but amplify an external seed. Understand the Technical Background To support your technical evaluation, this section includes links to authoritative encyclopedia articles for in-depth verification of the underlying physics, technical issues and techniques. While EDFAs dominate the C/ L bands (~1530–1600 nm) and Raman amplifiers enhance long-haul performance, other amplifier types extend coverage and functionality. Use the filters to narrow down on products based on your requirement. PDFA (Praseodymium Doped): Operates in the 1300nm band. SOA's work in a broader range, from 400-2000nm.

    [PDF Version]
  • What are the characteristics of a current transformer CT in relay protection

    What are the characteristics of a current transformer CT in relay protection

    Current transformers (CTs) are precision devices that translate primary currents into standard secondary values for relays and meters. Correct CT selection and application directly influence: Billing accuracy: Misapplied ratio or accuracy class can cause revenue leakage or disputes. They don't measure it directly. Instead, they scale it down so your gear doesn't get fried. They help with metering, spotting faults, and keeping things under. How are current transformers used in protection systems for power grids and substations? Current transformers (CTs) are the primary sensing interfaces between high-current power circuits and the low-voltage protection and metering equipment used in substations and transmission networks.

    [PDF Version]
  • Relay Protection Junior Electrician

    Relay Protection Junior Electrician

    The objective of relay protection is to quickly isolate a faulty section from both ends so that the rest of the system can function satisfactorily. The functional requirements of the relay:.


  • Relay protection warranty period

    Relay protection warranty period

    For the Relay+ device and any Relay accessory you purchase, one (1) year from the date of original retail purchase in its original packaging by you. of protection relays and is available even for relays as old as 40 years. Repair not only extends the lifetime of the relay, but functioning relay with a. As the durability (life) of the product varies greatly depending on the operating conditions and environment, the recommended maintenance and replacement timings are not specified. OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR. Relay, Inc.

    [PDF Version]
  • Dual-position relay protection principle

    Dual-position relay protection principle

    The principle is to grade the operating times of the relays in such a way that the relay closest to the fault spot operates first. Protective relays and devices have been developed over 100 years ago to provide “last line” of defense for the electrical systems. Further, the duration of the voltage. Core idea: Protective relays monitor electrical quantities and command protective devices to isolate faults or abnormal operating conditions. Engineering use: Relays are used on feeders, transformers, buses, motors, generators, and transmission lines to protect equipment and improve system. The third edition of Protective Relaying incorporates information on new developments and topics in protective relaying that has emerged since the second edition was published. Eng, IEEE Life Fellow IEEE/IAS/I&CPSD Protection & Coordination WG Chair Jacobs Canada, Calgary, AB rasheek.

    [PDF Version]
  • What is the function of a relay protection pressure plate

    What is the function of a relay protection pressure plate

    Electromechanical relays can be classified into several different types as follows: "Armature"-type relays have a pivoted lever supported on a hinge or knife-edge pivot, which carries a moving contact. These relays may work on either alternating or direct current, but for alternating current, a shading coil on the pole is used to maintain contact force throughout the alternating current cycle. Because the air gap between t.


More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +27 64 827 3915
Address Unit 9, Highveld Technopark, 43 Atlas Road, Johannesburg, 2196, South Africa